Note
Go to the end to download the full example code
Surface Restricted Traces and Line Integral Convolution#
Utilze EnSight to investigate two types of surface streamlines: Surface Restricted Traces (using Particle Trace) and LIC (Line Integral Convolution)
Intended to work with EnSight version 24.2 or later
Start an EnSight session#
Launch and connect to an instance of EnSight. This example uses a local EnSight installation.
from ansys.pyensight.core import LocalLauncher
session = LocalLauncher().start()
# Setup shortcuts for long winded calls.
eocore = session.ensight.objs.core
eoutil = session.ensight.utils
Load a dataset#
Load Shuttle Session file included in the EnSight installation and render

session.ensight.objs.ensxml_restore_file(
f"{session.cei_home}/ensight{session.cei_suffix}gui/demos/Shuttle Basic.ens"
)
session.ensight.view.highlight_parts("OFF")
session.ensight.view_transf.fit(0)
session.show("image", width=800, height=600)
Option 1. Using Particle Trace to create Surface Restricted Traces#
Using a Particle Trace capability Parent Part and Emit part are the same part. Surface Restriction is ON. .. image:: /_static/05_srt_lic_1.png
emitter_part = eoutil.parts.select_parts_by_dimension(2)
parent_parts = emitter_part
npts = 1500 # number of emitters
vector_var = eocore.VARIABLES["Momentum"][0] # Vector variable to use
SRTpart = eoutil.parts.create_particle_trace_from_parts(
"SurfaceRestrictedTrace",
vector_var,
parts=emitter_part,
source_parts=parent_parts,
direction="+/-",
surface_restrict=True,
num_points=npts,
)
session.show("image", width=800, height=600)
Change Visual Attributes#
Modify the attributes of the Surface Restricted Traces to be visually closer to Flourescene or Titantiam Dioxide (experimental use)

SRTpart.colorbyrgb = [0, 1, 0]
SRTpart.OPAQUENESS = 0.25
session.show("image", width=800, height=600)
Try Line Integral Convolution (LIC) instead#
As we don’t already have a near-surface, non-zero vector defined we need to create ‘Offset’ Variable. Create Offset Variable for Value of Momentum at 2.e-5 distance into fluid domain Specify Offset Variable as the variable for LIC. Specify High Contrast and 1 length for the LIC Specify that we want to see LIC for the Shuttle Surface

SRTpart.VISIBLE = False
session.ensight.part.select_byname_begin("(CASE:Case 1)Shuttle")
session.ensight.variables.evaluate("OffsetVar = OffsetVar(plist,Momentum,2e-05)")
session.ensight.case.sft_variable("OffsetVar")
session.ensight.case.sft_contrast("ON")
session.ensight.case.sft_norm_length(1.000000)
session.ensight.part.select_byname_begin("(CASE:Case 1)Shuttle")
session.ensight.part.show_sft("ON")
session.show("image", width=800, height=600)
Thumbnail sphinx_gallery_thumbnail_path = ‘_static/05_srt_lic_3.png’
session.close()